Eiffel Spark Ultimate SN/CF series is formulated with fully synthetic base stocks and advanced technology additive system to provide extra high level of engine protection and performance. It is suitable for higher mileage gasoline and diesel powered modern automobiles requiring an API SN/CF specification, where very high viscosity index oils are preferred to provide much longer oil drain intervals & fuel efficiency in modern engines. It provides maximum protection in engines operating under severe conditions, including high-performance turbo-charged, supercharged gasoline and certain diesel multi-valve fuel injected systems.  

Eiffel Spark Ultimate series is suitable for use in following:

Latest automotive gasoline and diesel engines (without Diesel Particulate Filters or DPFs).
Passenger cars, SUVs, light trucks and vans.
Suitable for all petrol engines with multi-valve & turbo types and with or without catalytic converter.
Naturally aspirated or turbo-charged diesel engines in cars and light vans.
Fuel injected or indirect injection diesel engines fitted with blow-by recirculation systems.

Specifications Eiffel Spark Ultimate meets or exceeds following International and Builder specifications:

  • API SN, SM, SL, SJ,CF
  • MW Long Life- 01
  • ACEA A3/B3, A3/B4
  • VW 502 00/505 00
  • MB 229.3/ 229.5
  • Porsche A40

Typical Characteristics

Eiffel Spark Ultimate Test Method Units 0W-30 0W-40 0W-60
Density @ 15 0C ASTM D 4052 gm/cc 0.840 0.845 0.850
Viscosity @ 100 0C ASTM D 445 cSt 10.4 14.30 22.50
Viscosity @ 40 0C ASTM D 445 cSt 54.2 80.9 144.75
Viscosity Index ASTM D 2270 185 185 185
Pour Point ASTM D 97 °C -48 -48 -48
Flash Point (COC) ASTM D 92 °C 228 236 245
Total Base Number ASTM D 2896 mg KOH/g 10.2 10.2 10.2
Phosphorous ASTM D 4951 %wt 0.1 0.1 0.1
CCS Viscosity ASTM D 5293 cP 4050 @ -35 °C 4180 @ -35 °C 5550 @ -35 °C